Please ensure Javascript is enabled for purposes of website accessibility
REVIEW PAPER
Neuromonitoring – still highly controversial
,
 
 
 
More details
Hide details
1
Clinic of General, Oncological and Endocrynological Surgery of Provincial Polyclinic Hospital, Kielce, Poland
 
2
Department of Surgical Medicine with Laboratory of Medical Genetics, Institute of Medical Sciences, Collegium Medicum, Jan Kochanowski University, Kielce, Poland
 
 
Submission date: 2021-06-03
 
 
Final revision date: 2021-08-17
 
 
Acceptance date: 2021-09-03
 
 
Publication date: 2021-09-30
 
 
Medical Studies 2021;37(3):232-238
 
KEYWORDS
TOPICS
ABSTRACT
Recurrent laryngeal nerve (RLN) paralysis, although rare, is among the most serious complications of thyroid gland surgery. It effects the quality of life of the patient, increases the costs of hospitalization, and can be the cause of legal proceedings. Therefore, it is not surprising that for a long time, devices have been sought that minimize the risk of injury to the nerves. One of them is intraoperative neuromonitoring (IONM). Despite several decades of using neuromonitoring during thyroid gland surgeries, there is still much controversy concerning its effectiveness. The divergent results of various meta-analyses are probably associated with the lack of standardization and inappropriate use of the method. Indisputable benefits from the use of IONM were proven in high-risk surgeries, such as malignant cancer, overactive thyroid gland, recurrent goitre, or retrosternal goitre. Nerve monitoring can be carried out by intermittent (I-IONM) or continuous (C-IONM) stimulation. At present, increasing importance is attached to continuous monitoring, because it protects the nerve against injury in real time, and the surgeon is warned against performance of a dangerous manoeuvre. Neuromonitoring is safe and does not show undesirable effects. Even though its use increases the costs of surgery and hospitalization, it improves the quality of the procedure and ensures the safety of the patient and the surgeon.
REFERENCES (43)
1.
Caragacianu D, Kamani D, Randolph GW. Intraoperative monitoring: normative range associated with normal postoperative glottic function. Laryngoscope 2013; 123: 3026-3031.
 
2.
Delbridge L. Total thyroidectomy: the evolution of surgical technique. ANZ J Surg 2003; 73: 761-768.
 
3.
Jatzko GR, Lisborg PH, Müller MG, Wette VM. Recurrent nerve palsy after thyroid operations: principal nerve identification and a literature review. Surgery 1994; 115: 139-144.
 
4.
Cirocchi R, Arezzo A, D’Andrea V, Abraha I, Popivanov GI, Avenia N, Gerardi C, Henry BM, Randolph J, Barczyñski M. Intraoperative neuromonitoring versus visual nerve identification for prevention of recurrent laryngeal nerve injury in adults undergoing thyroid surgery. Cochrane Database Syst Rev 2019; 1: CD012483.
 
5.
Gür EO, Haciyanli M, Karaisli S, Haciyanli S, Kamer E, Acar T, Kumkumoglu Y. Intraoperative nerve monitoring during thyroidectomy: evaluation of signal loss, prognostic value and surgical strategy. Ann R Coll Surg Engl 2019; 101: 589-595.
 
6.
Sławeta N, Głuszek S. Effect of complicated thyroid surgical procedures on personal and professional life of patients. Pol Przegl Chir 2012; 84: 437-444.
 
7.
Hayward NJ, Grodski S, Yeung M, Johnson WR, Serpell J. Recurrent laryngeal nerve injury in thyroid surgery: a review. ANZ J Surg 2013; 83: 15-21.
 
8.
Ahrén B, Månsson B. Recurrent laryngeal nerve palsy after thyroid and parathyroid surgery. Experience from Lund University. Thyroidology 1992; 4: 87-89.
 
9.
Mishra A, Agarwal G, Agarwal A, Mishra SK. Safety and efficacy of total thyroidectomy in hands of endocrine surgery trainees. Am J Surg 1999; 178: 377-380.
 
10.
Chiang FY, Lu IC, Chen HC, Chen HY, Tsai CJ, Lee KW, Hsiao PJ, Wu CW. Intraoperative neuromonitoring for early localization and identification of recurrent laryngeal nerve during thyroid surgery. Kaohsiung J Med Sci 2010; 26: 633-639.
 
11.
Bai B, Chen W. Protective effects of intraoperative nerve monitoring (IONM) for recurrent laryngeal nerve injury in thyroidectomy: meta-analysis. Sci Rep 2018; 8: 7761.
 
12.
Shedd DP, Durham C. Electrical identification of the recurrent laryngeal nerve. I. Response of the canine larynx to electrical stimulation of the recurrent laryngeal nerve. Ann Surg 1966; 163: 47-50.
 
13.
Delgado TE, Bucheit WA, Rosenholtz HR, Chrissian S. Intraoperative monitoring of facila muscle evoked responses obtained by intracranial stimulation of the facila nerve: a more accurate technique for facila nerve dissection. Neurosurgery 1979; 4: 418-421.
 
14.
Kienast A, Richter C, Neumann HJ. Intraoperatives Neuromonitoring des Nervus laryngeus recurrens — routinemäßiger Einsatz in der Schilddrüsenchirurgie. In: Vielfalt und Einheit der Chirurgie: Humanität und Wissenschaft. (Kongreß der Deutschen Gesellschaft für Chirurgie; vol. 115). Herfarth C (ed.). Springer, Berlin 1998; 1058-1060.
 
15.
Randolph GW, Kobler JB, Wilkins J. Recurrent laryngeal nerve identification and assessment during thyroid surgery: laryngeal palpation. World J Surg 2004; 28: 755-760.
 
16.
Randolph GW, Dralle H, Abdullah H, Barczynski M, Bellantone R, Brauckhoff M, Carnaille B, Cherenko S, Chiang FY, Dionigi G, Finck C, Hartl D, Kamani D, Lorenz K, Miccolli P, Mihai R, Miyauchi A, Orloff L, Perrier N, Poveda MD, Romanchishen A, Serpell J, SitgesSerra A, Sloan T, Van Slycke S, Snyder S, Takami H, Volpi E, Woodson G. Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope 2011; 121 Suppl 1: S1-S16.
 
17.
Wu CW, Dionigi G, Chen HC, Chen HY, Lee KW, Lu IC, Chang PY, hsiao PJ, Ho KY, Chiang FY. Vagal nerve stimulation without dissecting the carotid sheath during intraoperative neuromonitoring of the recurrent laryngeal nerve in thyroid surgery. Head Neck 2013; 35: 1443-1447.
 
18.
Dionigi G, Chiang FY, Dralle H, Boni L, Rausei S, Rovera F, Piantanida E, Mangano A, Barczyński M, Randolph GW, Dionigi R, Ulmer C. Safety of neural monitoring in thyroid surgery. Int J Surg 2013; 11: S120-S126.
 
19.
Lorenz K, Schneider R, Machens A, Sekulla C, Randolph GW, Dralle H. Loss of signal in IONM and staged thyroid surgery. In: The Recurrent and Superior Laryngeal Nerves. 1st ed. Randolph GW (ed.). Springer, Cham 2016; 211-221.
 
20.
Goretzki PE, Schwarz K, Brinkmann J, Wirowski D, Lammers BJ. The impact of intraoperative neuromonitoring (IONM) on surgical strategy in bilateral thyroid diseases: is it worth the effort? World J Surg 2010; 34: 1274-1284.
 
21.
Melin M, Schwarz K, Lammers BJ, Goretzki PE. IONM-guided goiter surgery leading to two-stage thyroidectomy: indication and results. Langenbecks Arch Surg 2013; 398: 411-418.
 
22.
Schneider R, Randolph GW, Dionigi G, Wu CW, Barczynski M, Chiang FY, Al-Quaryshi Z, Angelos P, Brauckhoff K, Cernea CR, Chaplin J, Cheetham J, Davies L, Goretzki PE, Hartl D, Kamani D, Kandil E, Kyriazidis N, Liddy W, Orloff L, Scharpf J, Serpell J, Shin JJ, Sinclair CF, Singer MC, Snyder SK, Tolley NS, Van Slycke S, Volpi E, Witterick I, Wong RJ, Woodson G, Zafereo M, Dralle H. International neural monitoring study group guideline 2018 part I: Staging bilateral thyroid surgery with monitoring loss of signal. Laryngoscope 2018; 128 Suppl 3: S1-S17.
 
23.
Phelan E, Schneider R, Lorenz K, Dralle H, Kamani D, Potenza A, Sritharan N, Shin J, Randolph GW. Continuous vagal IONM prevents recurrent laryngeal nerve paralysis by revealing initial EMG changes of impending neuropraxic injury: a prospective, multicenter study. Laryngoscope 2014; 124: 1498-1505.
 
24.
Yang S, Zhou L, Lu Z, Ma B, Ji Q, Wang Y. Systematic review with meta-analysis of intraoperative neuromonitoring during thyroidectomy. Int J Surg 2017; 39: 104-113.
 
25.
Henry BM, Graves MJ, Vikse J, Sanna B, Pękala PA, Walocha JA, Barczyński M, tomaszewski KA. The current state of intermittent intraoperative neural monitoring for prevention of recurrent laryngeal nerve injury during thyroidectomy: a PRISMA-compliant systematic review of overlapping meta-analyses. Langenbecks Arch Surg 2017; 402: 663-673.
 
26.
Lombardi CP, Carnassale G, Damiani G, Acampora A, Raffaelli M, de Crea C, Bellantone R. The final countdown: is intraoperative, intermittent neuromonitoring really useful in preventing permanent nerve palsy? Evidence from a meta-analysis. Surgery 2016; 160: 1693-1706.
 
27.
Malik R, Linos D. Intraoperative neuromonitoring in thyroid surgery: a systematic review. World J Surg 2016; 40: 2051-2058.
 
28.
Pisanu A, Porceddu G, Podda M, Cois A, Uccheddu A. Systematic review with meta-analysis of studies comparing intraoperative neuromonitoring of recurrent laryngeal nerves versus visualization alone during thyroidectomy. J Surg Res 2014; 188: 152-161.
 
29.
Sanabria A, Ramirez A, Kowalski LP, Silver CE, Shaha AR, Owen RP, Suárez C, Khafif A, Rinaldo A, Ferlito A. Neuromonitoring in thyroidectomy: a meta-analysis of effectiveness from randomized controlled trials. Eur Arch Otorhinolaryngol 2013; 270: 2175-2189.
 
30.
Sun W, Liu J, Zhang H, Zhang P, Wang Z, Dong W, He L, Zhang T. A meta-analysis of intraoperative neuromonitoring of recurrent laryngeal nerve palsy during thyroid reoperations. Clin Endocrinol 2017; 87: 572-580.
 
31.
Wong KP, Mak KL, Wong CKH, Lang BHH. Systematic review and meta-analysis on intra-operative neuro-monitoring in high-risk thyroidectomy. Int J Surg 2017; 38: 21-30.
 
32.
Zheng S, Xu Z, Wei Y, Zeng M, He J. Effect of intraoperative neuromonitoring on recurrent laryngeal nerve palsy rates after thyroid surgery: a meta-analysis. J Formos Med Assoc 2013; 112: 463-472.
 
33.
Schneider R, Machens A, Lorenz K, Dralle H. Intraoperative nerve monitoring in thyroid surgery-shifting current paradigms. Gland Surg 2020; 9 (Suppl 2): S120-S128.
 
34.
Schneider R, Randolph GW, Sekulla C, Phelan E, Thanh PN, Bucher M, Machens A, Dralle H, Lorenz K. Continuous intraoperative vagus nerve stimulation for identification of imminent recurrent laryngeal nerve injury. Head Neck 2013; 35: 1591-1598.
 
35.
Godballe C, Madsen AR, Sørensen CH, Schytte S, Trolle W, Helweg-Larsen J, Barfoed L, Kristiansen L, Sørensen VZ, Samuelsen G, Pedersen HB. Risk factors for recurrent nerve palsy after thyroid surgery: a national study of patients treated at Danish departments of ENT Head and Neck Surgery. Eur Arch Otorhinolaryngol 2014; 271: 2267-2276.
 
36.
Chiang FY, Wang LF, Huang YF, Lee KW, Kuo WR. Recurrent laryngeal nerve palsy after thyroidectomy with routine identification of the recurrent laryngeal nerve. Surgery 2005; 137: 342-347.
 
37.
Feng AL, Puram SV, Singer MC, Modi R, Kamani D, Randolph GW. Increased prevalence of neural monitoring during thyroidectomy: global surgical survey. Laryngoscope 2020; 130: 1097-1104.
 
38.
Marti JL, Holm T, Randolph G. Universal use of intraoperative nerve monitoring by recently fellowship-trained thyroid surgeons is common, associated with higher surgical volume, and impacts intraoperative decision-making. World J Surg 2016; 40: 337-343.
 
39.
Bartsch DK, Dotzenrath C, Vorländer C, Zielke A, Weber T, Buhr HJ, Klinger C, Lorenz K. Current Practice of Surgery for Benign Goitre – An Analysis of the Prospective DGAV StuDoQ Thyroid Registry. J Clin Med 2019; 8: 477.
 
40.
Dionigi G, Bacuzzi A, Boni L, Rausei S, Rovera F, Dionigi R. Visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy: what about the costs? World J Surg 2012; 36: 748-754.
 
41.
Wang T, Kim HY, Wu CW, Rausei S, Sun H, Pergolizzi FP, Dionigi G. Analyzing cost-effectiveness of neural-monitoring in recurrent laryngeal nerve recovery course in thyroid surgery. Int J Surg 2017; 48: 180-188.
 
42.
Gremillion G, Fatakia A, Dornelles A, Amedee RG. Intraoperative recurrent laryngeal nerve monitoring in thyroid surgery: is it worth the cost? Ochsner J 2012; 12: 363-366.
 
43.
Dralle H, Lorenz K, Machens A. Verdicts on malpractice claims after thyroid surgery: emerging trends and future directions. Head Neck 2012; 34: 1591-1596.
 
eISSN:2300-6722
ISSN:1899-1874
Journals System - logo